Absperrschieber

  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 42″
    Bewertung: 600lb
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A216 WCB+STELLITE 6, FLEXIBLER KEIL, VOLLER ANSCHLUSS
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: LIMITORQUE SMC-5 480 V AC, 3 PH, 60 Hz, mit manueller Umschaltung.
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 20″*16″
    Bewertung: 300lb 600lb
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A216 WCB+STELLITE 6, FLEXIBLER KEIL
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: LIMITORQUE INTELLIGENTER MODULIERENDER TYP, 4-20 mA-Signal, 480 V AC, 3 PH, 60 Hz, MIT MANUELLER ÜBERSTEUERUNG.
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 8″
    Bewertung: 600lb
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A216 WCB+STELLITE 6, FLEXIBLER KEIL
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: GETRIEBE
  • Größe: 2″~24”
    Bewertung: 150LB
    Materialien:
    ASTM A536 65-45-12 Gehäuse und Haube, epoxidbeschichtet
    ASTM A536 65-45-12+EPDM-beschichtete Scheibe
    ASTM A182 F6A Schaft
    Integrierter Sitz
    Bedienung: Handrad
    Enden: Flansch gemäß ANSI B16.1
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 8″
    Bewertung: 600lb
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A216 WCB+STELLITE 6, FEST
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: GETRIEBE
  • FOTOS ZEIGEN SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 16″
    Bewertung: 1500lb
    KÖRPER: ASTM A182 F91
    SCHEIBE: ASTM A182 F91
    FEDER: INCONEL X-750
    STAMM: ASTM A182 F91
    SITZ: ASTM A182 F91 AUSTAUSCHBAR.
    BETÄTIGUNG: GETRIEBE
  • FOTOS ZEIGEN SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: DN200
    BEWERTUNG: PN420
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A182 F304+STELLITE 6, FEST
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: RAD
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 8″
    Bewertung: 600lb
    GEHÄUSE UND HAUBE: ASTM A216 WCB
    SCHEIBE: ASTM A216 WCB+STELLITE 6, FLEXIBLER KEIL
    STAMM: ASTM A182 F6A
    SITZ: ASTM A105+STELLITE 6
    BETÄTIGUNG: GETRIEBE
  • Konstruktionsstandard: API 600 / ASME B16.34
    Größe: 16 Zoll (NPS 16)
    Druckklasse: ASME Klasse 1500 (1500 LB)
    Gehäuse- und Haubenmaterial: ASTM A182 F91 (9Cr-1Mo-V Schmiedestahl)
    Haubentyp: Druckdichtung (selbstdichtende) Haube
    Endverbindung: Stumpfschweißung (BW) gemäß ASME B16.25
    Sitzringe: Vollständige Stellite 6-Auflage (mind. 3 mm)
    Schieberplatten: Stellite 6-gepanzerte Kontaktflächen
    Schaftmaterial: ASTM A182 F6a (Oberfläche nitriert HRC≥40)
    Schafttyp: Steigender Schaft (OS&Y) mit Anti-Blowout-Design
    Verpackung: Flexible Graphitringe (feuersicher gemäß API 607)
    Dichtung: Druckdichtring (Typ Inconel 600 RTJ)
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 1″
    Bewertung: 800lb
    ENDE: SW GEMÄSS ASME B16.11
    TEMPERATUR: -196 ℃
    KAROSSERIE UND MOTORHAUBE: ASTM A182 F304
    KEIL: FEST ASTM A182 F304+HF
    STAMM: ASTM A182 F304
    SITZ: HF-METALL
    BETÄTIGUNG: HANDRAD
  • • Größe: 3″
    • Bewertung: 125 lb
    • Werkstoffe: Körper, Haube und Keil ASTM A126 GR.B
    • Stimme 410SS
    • U-Bolzen aus Kohlenstoffstahl
    • Bedienung: Handrad
  • FOTO ZEIGT SPEZIFIKATIONEN WIE UNTEN
    GRÖSSE: 2″
    Bewertung: 150lb
    KAROSSERIE UND MOTORHAUBE: C95500
    SCHEIBE: C95500 SOLID
    SCHAFT: MONEL K500
    SITZ: MONEL K500
    BETÄTIGUNG: RAD

A gate valve is a type of valve used to completely stop or allow flow in a pipeline by raising or lowering a solid barrier (the gate) into the path of the fluid. It is primarily designed for on/off control rather than flow regulation. When the valve is fully open, the gate is entirely lifted, allowing unobstructed flow with minimal pressure drop. When closed, the gate seals tightly to stop flow entirely. Gate valves are most effective in systems where the valve remains either fully open or fully closed for extended periods. They are not ideal for throttling purposes because the partially open gate can vibrate, causing wear and potentially damaging the valve. These valves are widely used in water supply systems, oil and gas pipelines, and industrial applications due to their robust construction and ability to handle high pressures and temperatures. Common materials include cast iron, stainless steel, and brass, with options tailored to specific media and environments. Gate valves are known for their durability, tight sealing, and long service life, making them a preferred choice in many heavy-duty applications.

What Are The Advantages Of Using A Gate Valve?

Gate valves offer several advantages that make them a popular choice for a wide range of industries. One of the key benefits is their low pressure drop when fully open, which helps maintain system efficiency. Their straight-through flow design minimizes turbulence and energy loss. Gate valves also provide a reliable shutoff, which is crucial for isolating sections of piping during maintenance or emergencies. Because they are designed for full open or closed positions, gate valves reduce wear and extend service life when used properly. Their versatility in handling different types of fluids—such as water, steam, oil, and gas—adds to their appeal. In addition, gate valves are available in various sizes and materials, which makes them suitable for everything from household plumbing to large-scale industrial systems. They can be installed in both horizontal and vertical orientations, offering flexibility in system design. With proper installation and minimal maintenance, gate valves deliver long-term, dependable performance even in demanding environments.

Gate Valves FAQ

  • 1.What is a gate valve used for?

    It’s used to start or stop the flow in a pipeline.

  • 2.Can a gate valve be used for flow control?

    No, it’s not suitable for throttling.

  • 3.Is a gate valve better than a ball valve?

    Each has different uses—gate valves are better for isolation in large systems.

  • 4.What media can gate valves handle?

    They can handle water, oil, gas, steam, and slurry.

  • 5.How do I know if a gate valve is open or closed?

    In rising stem types, the stem position indicates the valve status.

Wenn Sie an unseren Produkten interessiert sind, können Sie Ihre Informationen hier hinterlassen und wir werden uns in Kürze mit Ihnen in Verbindung setzen.