Šoupátkové ventily

  • FOTOGRAFIE ZOBRAZUJE NÍŽE UVEDENÉ SPECIFIKACE
    VELIKOST: 42″
    HODNOCENÍ: 600 LB
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A216 WCB+STELLITE 6, FLEXIBILNÍ KLÍN, PLNÝ PORT
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: LIMITORQUE SMC-5 480V AC, 3PH, 60HZ, S RUČNÍM PŘEPNUTÍM.
  • FOTOGRAFIE ZOBRAZUJE NÍŽE UVEDENÉ SPECIFIKACE
    VELIKOST: 20″*16″
    HODNOCENÍ: 300LB 600LB
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A216 WCB+STELLIT 6, FLEXIBILNÍ KLÍN
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: INTELIGENTNÍ MODULACE S LIMITORQUE, signál 4–20 mA, 480 V AC, 3 fáze, 60 Hz, s manuálním ovládáním.
  • SIZE: 25A (1")
    RATING: JIS 5K
    DESIGN: API 602 12th EDITION
  • Velikost: 2″~24”
    Hodnocení: 150 liber
    Materiály:
    Těleso a víko ASTM A536 65-45-12, s epoxidovým nátěrem
    Kotouč s povlakem ASTM A536 65-45-12+EPDM
    Vřeteno ASTM A182 F6A
    Integrované sedadlo karoserie
    Obsluha: ruční kolo
    Konce: Příruba dle ANSI B16.1
  • FOTOGRAFIE ZOBRAZUJE NÍŽE UVEDENÉ SPECIFIKACE
    VELIKOST: 8″
    HODNOCENÍ: 600 LB
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A216 WCB+STELLIT 6, FLEXIBILNÍ KLÍN
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: PŘEVODOVKA
  • Valve Type Flexible Wedge Gate Valve
    Size Range ¼” to 4″ (DN8 to DN100)
    Pressure Class 150LB · 300LB · 600LB · 900LB · 1500LB
    End Connections Socket Weld (SW) · NPT · Raised Face Flange (RF)
    Body/Bonnet ASTM A105 Forged Carbon Steel
    Trim Package F6a Hardfaced
    Gate Disc A105 + Stellite 6
    Stem ASTM A182 F6a (13Cr SS)
    Seats Integral Stellite 6 overlay
    Gasket Spiral Wound SS316/Graphite
    Operation Handwheel (Standard) · Gear Operator (Opt)
  • FOTOGRAFIE ZOBRAZUJE NÍŽE UVEDENÉ SPECIFIKACE
    VELIKOST: 8″
    HODNOCENÍ: 600 LB
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A216 WCB+STELLIT 6, PEVNÝ
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: PŘEVODOVKA
  • FOTOGRAFIE UKAŽUJÍ SPECIFIKACE NÍŽE
    VELIKOST: 16″
    HODNOCENÍ: 1500LB
    TĚLO: ASTM A182 F91
    DISK: ASTM A182 F91
    PRUŽINA: INCONEL X-750
    STEM: ASTM A182 F91
    SEDLO: VYMĚNITELNÉ dle ASTM A182 F91.
    OVLÁDÁNÍ: PŘEVODOVKA
  • FOTOGRAFIE UKAŽUJÍ SPECIFIKACE NÍŽE
    VELIKOST: DN200
    HODNOCENÍ: PN420
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A182 F304+STELLIT 6, PEVNÝ
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: KOLEČKO
  • FOTOGRAFIE ZOBRAZUJE NÍŽE UVEDENÉ SPECIFIKACE
    VELIKOST: 8″
    HODNOCENÍ: 600 LB
    TĚLO A KAPOTA: ASTM A216 WCB
    KOTOUČ: ASTM A216 WCB+STELLIT 6, FLEXIBILNÍ KLÍN
    STEM: ASTM A182 F6A
    SEDLO: ASTM A105+STELLITE 6
    OVLÁDÁNÍ: PŘEVODOVKA
  • Konstrukční norma: API 600 / ASME B16.34
    Velikost: 16 palců (NPS 16)
    Tlaková třída: ASME třída 1500 (1500 LB)
    Materiál tělesa a víka: ASTM A182 F91 (kovaná ocel 9Cr-1Mo-V)
    Typ kapoty: Tlaková (samotěsnící) kapota
    Koncové spojení: Tupý svar (BW) dle ASME B16.25
    Sedlové kroužky: Plně stelitové 6 potažení (min. 3 mm)
    Desky brány: Kontaktní plochy s tvrdým navařováním Stellite 6
    Materiál dříku: ASTM A182 F6a (povrchová nitridace HRC ≥40)
    Typ vřetene: Stoupající vřeteno (OS&Y) s konstrukcí proti přepálení
    Balení: Flexibilní grafitové kroužky (ohnivzdorné dle API 607)
    Těsnění: Těsnicí kroužek (typ Inconel 600 RTJ)
  • FOTOGRAFIE ZOBRAZUJE SPECIFIKACI NÍŽE
    VELIKOST: 2,5 cm
    HODNOCENÍ: 800 LB
    KONEC: SW DLE ASME B16.11
    TEPLOTA: -196 ℃
    TĚLO A KAPOTA: ASTM A182 F304
    KLÍN: PŘÍLOHA ASTM A182 F304+HF
    STEM: ASTM A182 F304
    SEDÁK: HF KOV
    OVLÁDÁNÍ: RUČNÍ KOLO

A gate valve is a type of valve used to completely stop or allow flow in a pipeline by raising or lowering a solid barrier (the gate) into the path of the fluid. It is primarily designed for on/off control rather than flow regulation. When the valve is fully open, the gate is entirely lifted, allowing unobstructed flow with minimal pressure drop. When closed, the gate seals tightly to stop flow entirely. Gate valves are most effective in systems where the valve remains either fully open or fully closed for extended periods. They are not ideal for throttling purposes because the partially open gate can vibrate, causing wear and potentially damaging the valve. These valves are widely used in water supply systems, oil and gas pipelines, and industrial applications due to their robust construction and ability to handle high pressures and temperatures. Common materials include cast iron, stainless steel, and brass, with options tailored to specific media and environments. Gate valves are known for their durability, tight sealing, and long service life, making them a preferred choice in many heavy-duty applications.

What Are The Advantages Of Using A Gate Valve?

Gate valves offer several advantages that make them a popular choice for a wide range of industries. One of the key benefits is their low pressure drop when fully open, which helps maintain system efficiency. Their straight-through flow design minimizes turbulence and energy loss. Gate valves also provide a reliable shutoff, which is crucial for isolating sections of piping during maintenance or emergencies. Because they are designed for full open or closed positions, gate valves reduce wear and extend service life when used properly. Their versatility in handling different types of fluids—such as water, steam, oil, and gas—adds to their appeal. In addition, gate valves are available in various sizes and materials, which makes them suitable for everything from household plumbing to large-scale industrial systems. They can be installed in both horizontal and vertical orientations, offering flexibility in system design. With proper installation and minimal maintenance, gate valves deliver long-term, dependable performance even in demanding environments.

Gate Valves FAQ

  • 1.What is a gate valve used for?

    It’s used to start or stop the flow in a pipeline.

  • 2.Can a gate valve be used for flow control?

    No, it’s not suitable for throttling.

  • 3.Is a gate valve better than a ball valve?

    Each has different uses—gate valves are better for isolation in large systems.

  • 4.What media can gate valves handle?

    They can handle water, oil, gas, steam, and slurry.

  • 5.How do I know if a gate valve is open or closed?

    In rising stem types, the stem position indicates the valve status.