TECHNICAL DATA SHEET
Product: 1″ – Class 600 Y‑Pattern Strainer
Material: ASTM A105 (Forged Carbon Steel)
- General Description
This Y‑pattern strainer is designed for 1″ (DN25) Class 600 service. The forged ASTM A105 carbon steel body provides high strength and reliability for high‑pressure applications in oil & gas, petrochemical, power generation, and industrial fluid systems. The Y‑type configuration offers a low pressure drop while enabling efficient removal of pipeline debris, protecting downstream equipment such as pumps, meters, and control valves.
- Specifikace
Parametr | Value |
Velikost | 1″ (DN25) |
Jmenovitý tlak | Class 600 (ASME B16.34) |
Design Type | Y‑pattern, bolted cover |
End Connections | [e.g., Raised Face (RF) / Ring Type Joint (RTJ) flanges to ASME B16.5, or socket weld / NPT to ASME B16.11] |
Screening | Perforated basket or mesh screen (see options) |
Filtration Rating | [e.g., 0.5 mm – 3.0 mm perforation / 20 – 200 mesh] |
Applicable Media | Water, oil, gas, steam, condensate, non‑aggressive fluids |
Teplotní rozsah | -29°C to +425°C (depending on gasket & screen material) |
Flow Direction | Arrow on body indicates flow (fluid enters cap side, exits opposite) |
- Material Specification
Item | Component | Materiál | Norma |
1 | Tělo | Carbon Steel | ASTM A105 (forged) |
2 | Cover | Carbon Steel | ASTM A105 (forged) |
3 | Screen / Basket | Stainless Steel 304 / 316 | ASTM A240 |
4 | Gasket | Spiral Wound (SS/Graphite) / PTFE | — |
5 | Cover Bolting | Alloy Steel | ASTM A193 B7 |
6 | Drain Plug (optional) | Carbon Steel / Stainless Steel | — |
- Klíčové vlastnosti
- Forged Carbon Steel Construction: ASTM A105 provides excellent mechanical properties, toughness, and reliable performance at elevated pressures and temperatures.
- Y‑Pattern Design: Angled screen chamber minimizes pressure drop and allows continuous flow even when the screen is partially loaded.
- Easy Maintenance: Bolted cover enables quick removal of the screen for cleaning or replacement without removing the strainer from the pipeline.
- Versatile End Connections: Available in flanged, socket weld, or NPT configurations to suit various piping systems.
- Optional Blow‑Down Connection: A tapped drain port can be provided for periodic flushing without cover removal.
- Magnetic Insert Option: Available for capturing ferrous particles in critical applications.
- Screen Options
Type | Popis | Typical Application |
Perforated Basket | 0.5 mm – 3.0 mm hole diameter | Coarse straining, high flow, low pressure drop |
Mesh Liner | 20 – 200 mesh (stainless steel) | Fine filtration of particulates |
Dual Layer (Perforated + Mesh) | Combines strength with fine filtration | General purpose, demanding applications |
- Dimensional Data (Typical for 1″ Class 600)
Parametr | Value |
Face‑to‑Face (Flanged) | [e.g., 180 mm / 7.1″ per ASME B16.10] |
End Flange Dimensions | ASME B16.5 Class 600 RF / RTJ |
Overall Height | [e.g., 120 mm / 4.7″] |
Cover Bolts | [e.g., 4 × studs, size ½″‑13] |
Weight (Approx.) | [e.g., 6.5 kg / 14 lbs] |
Note: Dimensions vary by manufacturer; refer to certified drawings.
- Testing & Compliance
- Design & Manufacturing: ASME B16.34 / MSS SP‑25 / MSS SP‑45
- End Flange Dimensions: ASME B16.5
- Socket Weld / Threaded Ends: ASME B16.11
- Pressure Testing: API 598 / MSS SP‑61 (shell and seat)
- Material Certification: EN 10204 Type 3.1 (chemical & mechanical)
- NACE (Optional): MR0175 / MR0103 for sour service
- Aplikace
- Oil & gas production and refining
- Petrochemical plants
- Power generation (steam, boiler feedwater, cooling water)
- High‑pressure water injection systems
- Industrial process lines requiring upstream filtration
- Ordering Information
Please specify the following when ordering:
Parametr | Options |
End Connections | Flanged RF / RTJ / Socket Weld / NPT |
Screen Type | Perforated (hole size) / Mesh (mesh count) / Dual layer |
Gasket Material | Spiral wound (SS/Graphite) / PTFE / Flexible graphite |
Drain Port | Yes (with plug) / No |
Magnetic Insert | Yes / No |
Special Requirements | NACE MR0175 / Positive material identification (PMI) / Low‑temp impact test |
- Notes
- Installation: Ensure flow direction matches the arrow on the body. The screen should be accessible for periodic cleaning.
- Maintenance: Regularly inspect and clean the screen to prevent excessive pressure drop. Replace gaskets and bolts according to recommended torque values.
- Pressure Drop: For accurate sizing, refer to the manufacturer’s flow coefficient (Cv) and screen open‑area data.
ZÁRUKA:
Společnost SAVVY VALVES se zavazuje poskytovat výjimečnou kvalitu produktů a bezstarostný poprodejní servis. Naše ventily mají zaručenou minimální životnost 12 měsíců, během níž zdarma dodáme všechny potřebné náhradní díly a podrobné pokyny k údržbě. V případě poškození, které není způsobeno lidskou činností, v rámci záruční doby bezplatně vyměníme komponenty a poskytneme profesionální technickou podporu. Po uplynutí záruky zákazníci uhradí pouze náklady na náhradní díly a zároveň mohou využívat zlevněné služby údržby. Naším cílem je pomáhat klientům snižovat provozní náklady a zvyšovat efektivitu výroby prostřednictvím spolehlivé kvality a komplexní poprodejní podpory. Ať už se jedná o technické dotazy nebo potřeby údržby, náš tým odborníků vám promptně zareaguje, aby zajistil, že váš ventilový systém bude vždy udržovat optimální výkon.