Twój grill Grille drewniane Grill na pellet
kriogeniczny zawór kulowy
cryogenic control valve
cryogenic valves
cryogenic valves pdf
lng cryogenic valves
valve cryogenic
Design & Manufacture BS 6364, ISO 28921-1, MSS SP-134, ASME B16.34
Face-to-Face Dimension BS 6364 Table 1, ISO 5752 Series 11 (Extended)
End Connections ASME B16.5 (RF/RTJ), EN 1092-1, GB/T 9113, JB/T 79
Butt Weld Ends ASME B16.25, GB/T 12224
Socket Weld / Thread ASME B16.11, NPT/BSPT per ISO 7-1
Pressure Testing API 598, ISO 5208, BS 6364 Annex A (Cryogenic)



Description
TECHNICAL DATA SHEET
Forged Stainless Steel Cryogenic Floating Ball Valve
Series: DQ41F/Y / DQ61F/Y
Models: Reduced Bore / Full Bore, Side-Entry (Split Body)
This forged stainless steel cryogenic ball valve is specifically engineered for reliable shut-off and flow control of liquefied gases and cryogenic fluids down to -196°C. Designed in accordance with BS 6364, ISO 28921-1, and MSS SP-134 standards, it features a two-piece bolted body construction with extended bonnet and fully forged austenitic stainless steel components (ASTM A182 F304/F304L/F316L) to eliminate porosity and ensure structural integrity under extreme thermal cycling .
Key Features:
|
Item |
Standard / Code |
|
Design & Manufacture |
BS 6364, ISO 28921-1, MSS SP-134, ASME B16.34 |
|
Face-to-Face Dimension |
BS 6364 Table 1, ISO 5752 Series 11 (Extended) |
|
End Connections |
ASME B16.5 (RF/RTJ), EN 1092-1, GB/T 9113, JB/T 79 |
|
Butt Weld Ends |
ASME B16.25, GB/T 12224 |
|
Socket Weld / Thread |
ASME B16.11, NPT/BSPT per ISO 7-1 |
|
Pressure Testing |
API 598, ISO 5208, BS 6364 Annex A (Cryogenic) |
|
Fugitive Emission |
ISO 15848-1 Class B |
|
Fire Safe (Optional) |
API 607 / ISO 10497 |
|
Antystatyczny |
ISO 28921-1, BS 5353 |
|
NACE |
MR0175 / ISO 15156 (Optional) |
|
SIL Rating |
SIL 3 Capable (IEC 61508) |
|
Parametr |
Specyfikacja |
|
Typ zaworu |
Floating Ball, Side-Entry (2-Piece Split Body), Anti-blowout Stem |
|
Size Range |
DN15 ~ DN300 (½” ~ 12″) |
|
Pressure Classes |
ASME Class 150, 300, 600 (PN16 ~ PN100) |
|
Temperature Range |
-196°C ~ +80°C (Standard Cryogenic) |
|
Design Temperature |
-196°C (Liquid Nitrogen) |
|
Minimum Design Temp |
-196°C (316L), -101°C (LC3), -46°C (LCB) |
|
Service Media |
LNG, LN₂, LO₂, LAr, LHe, Ethylene, Liquid Propane, Ammonia, CO₂, Hydrogen |
|
Flow Pattern |
Full Bore (Regular) / Reduced Bore (Optional) |
|
Flow Direction |
Uni-directional (Standard), Bi-directional (Optional) |
|
Działanie |
Manual (Lever/Gear), Pneumatic (DA/SR), Electric |
|
Mounting |
ISO 5211 top flange for direct actuator mounting |
|
Insulation |
Extended bonnet suitable for cold box installation |
|
Część |
Material (ASTM) |
Notatki |
|
Body Halves |
A182 F304/F304L (Forged) |
Carbon ≤ 0.03%, cryogenic stabilization treated, -196°C impact ≥ 50J |
|
Bonnet (Extension) |
A182 F304/F304L (Forged) |
Extended length per BS 6364, integrally forged or welded construction |
|
Piłka |
A182 F304/F304L (Forged) |
Chrome-nickel austenitic, surface Ra ≤ 0.4μm, floating design |
|
Trzon |
A182 F304/F304L/F316L (Forged) |
Anti-blowout shoulder, cryogenic nitrogen hardening optional |
|
Seat Rings |
RPTFE (Glass/Carbon Fiber Reinforced) / PCTFE / PEEK |
Spring-energized for low-temp sealing |
|
Seal Carrier |
A182 F304/F304L |
– |
|
Stem Packing |
Graphite Foil + RPTFE, Live-loaded with Belleville springs |
Low emission, ISO 15848-1 Class B |
|
Gaskets |
Spiral Wound (SS316L/Graphite) |
– |
|
Body Bolting |
ASTM A193 B8M Class 2 (Stainless) |
High strength, low-temperature compatible |
|
Nuts |
ASTM A194 8M |
– |
|
Thrust Washer |
RPTFE / PTFE + Bronze |
Anti-extrusion, low friction |
|
Urządzenie antystatyczne |
SS316L Spring + Plunger |
Resistance ≤ 10Ω |
|
Handle / Gearbox |
SS304 / Ductile Iron |
– |
Alternative Forged Materials (Upon Request):
Cryogenic Stabilization Process:
Purpose:
Impact Testing:
6.1 Flanged Type (DQ41F/Y) – PN16/PN40 / Class 150/300
Unit: mm (Reference dimensions – subject to manufacturer design)
|
DN |
Size (in) |
L (RF) |
L (RTJ) |
D (Class 150) |
D (Class 300) |
Bonnet Extension H |
Approx. Weight (kg) |
|
15 |
½” |
130 |
140 |
95 |
95 |
230 |
3.0 |
|
20 |
¾” |
140 |
152 |
105 |
105 |
260 |
4.0 |
|
25 |
1″ |
150 |
165 |
115 |
115 |
280 |
5.0 |
|
32 |
1¼” |
165 |
178 |
135 |
135 |
290 |
9.0 |
|
40 |
1½” |
180 |
190 |
145 |
145 |
320 |
11.0 |
|
50 |
2″ |
203 |
216 |
160 |
165 |
340 |
15.0 |
|
65 |
2½” |
222 |
241 |
180 |
190 |
370 |
19.0 |
|
80 |
3″ |
241 |
283 |
195 |
210 |
400 |
27.0 |
|
100 |
4″ |
305 |
305 |
215 |
255 |
450 |
38.0 |
|
150 |
6″ |
394 |
403 |
280 |
320 |
550 |
81.0 |
|
200 |
8″ |
457 |
502 |
345 |
380 |
680 |
95.0 |
|
250 |
10″ |
533 |
568 |
405 |
445 |
790 |
140.0 |
|
300 |
12″ |
610 |
648 |
485 |
520 |
890 |
200.0 |
Notatki:
6.2 Socket Weld / Threaded Type (DQ61F/Y) – NPT/BSPT/SW
Unit: mm
|
DN |
Inch |
L |
d (Bore) |
D (Socket) |
D1 (Thread) |
H (Extension) |
W (Handle) |
|
15 |
½” |
92 |
13 |
36 |
21.8 |
230 |
160 |
|
20 |
¾” |
111 |
18 |
42 |
27.3 |
260 |
220 |
|
25 |
1″ |
127 |
23 |
52 |
33.8 |
280 |
220 |
|
32 |
1¼” |
140 |
28 |
60 |
42.6 |
290 |
250 |
|
40 |
1½” |
152 |
35 |
68 |
48.7 |
320 |
250 |
|
50 |
2″ |
178 |
45 |
80 |
61.2 |
340 |
350 |
Source:
Forged A182 F304/F304L – ASME B16.34
|
Temperature (°C) |
Class 150 (psi) |
Class 300 (psi) |
Class 600 (psi) |
|
-29 to +38 |
285 |
740 |
1480 |
|
+50 |
270 |
705 |
1410 |
|
+100 |
235 |
615 |
1230 |
|
-196°C (Derated) |
230 |
600 |
1200 |
Critical Notes:
|
Test Type |
Standard |
Criteria |
|
Shell Hydrostatic Test |
API 598 / ISO 5208 |
1.5 × rated pressure at ambient, no visible leakage |
|
High-Pressure Pneumatic Test |
API 598 |
0.6 MPa (80 psi) air, soap bubble test |
|
Cryogenic Seat Leakage Test |
BS 6364 Annex A |
Valve immersed in LN₂ (-196°C), 1.1× rated pressure, max leakage: 0.1 Nm³/hr × DN (mm) for gas |
|
High-Performance Cryogenic Leakage |
AOKAVI / ISO 28921-1 |
≤ 1×10⁻⁹ mL/min (Helium) at -196°C |
|
Fugitive Emission (Stem) |
ISO 15848-1 Class B |
≤ 10⁻⁵ mbar·L/s (Helium) |
|
Anti-Static Test |
ISO 28921-1 |
Resistance ≤ 10Ω between stem and body |
|
Fire Safe (Optional) |
API 607 |
Per API 607 7th Edition |
|
DN |
Rozmiar |
Torque (N·m) @ ΔP=40 bar |
Actuator Recommendation |
|
15 |
½” |
8 – 12 |
Manual Lever / Small Pneumatic |
|
25 |
1″ |
20 – 30 |
Dźwignia ręczna |
|
50 |
2″ |
80 – 120 |
Manual Lever / Gear |
|
80 |
3″ |
180 – 250 |
Gear / Pneumatic |
|
100 |
4″ |
300 – 400 |
Gear / Pneumatic |
|
150 |
6″ |
700 – 900 |
Gearbox / Pneumatic |
Notatki:
Extended Bonnet (Long Neck):
Pressure Relief Mechanism:
Urządzenie antystatyczne:
Oxygen Service Cleaning:
|
Industry |
Typical Media |
Temperatura |
|
LNG / LPG |
Methane, Ethane, Propane, Butane |
-162°C to -46°C |
|
Industrial Gases (Air Separation) |
Liquid Nitrogen (LN₂), Liquid Oxygen (LO₂), Liquid Argon (LAr) |
-196°C to -183°C |
|
Hydrogen Energy |
Liquid Hydrogen (LH₂) |
-253°C (Inconel/Ti req’d) |
|
Petrochemical |
Ethylene, Propylene |
-104°C |
|
Refrigeration |
Ammonia (R717), CO₂ (R744) |
-46°C to -78°C |
|
Cryogenic Storage |
Liquid Helium (LHe) |
-269°C (Special alloy) |
|
Aerospace |
Rocket propellants (LO₂, LH₂) |
-253°C to -183°C |
|
Pharmaceutical / Biotech |
Liquid nitrogen freezing |
-196°C |
|
Certification |
Scope |
Availability |
|
BS 6364 |
Cryogenic valve design & testing |
Standard |
|
ISO 28921-1 |
Industrial cryogenic valves |
Standard |
|
PED 2014/68/EU |
Category III, Module H |
Optional |
|
TA-Luft (VDI 2440) |
Fugitive emission |
Optional |
|
API 607 |
Fire safe testing |
Optional |
|
NACE MR0175 |
Sour service |
Optional |
|
ATEX 2014/34/EU |
Explosive atmospheres (Zone 1/2) |
Optional |
|
ISO 9001:2015 |
Quality management |
Standard |
|
EN 10204 3.1/3.2 |
Material certification |
Optional |
To ensure correct valve selection for your cryogenic application, please specify:
GWARANCJA:
SAVVY VALVES zobowiązuje się do dostarczania wyjątkowej jakości produktów i bezproblemowej obsługi posprzedażowej. Gwarantujemy, że nasze zawory zapewnią minimalny okres eksploatacji wynoszący 12 miesięcy, podczas którego dostarczymy bezpłatnie wszystkie niezbędne części zamienne i szczegółowe instrukcje dotyczące konserwacji. W okresie gwarancyjnym, jeśli wystąpią jakiekolwiek uszkodzenia niespowodowane przez człowieka, wymienimy komponenty bezpłatnie i zapewnimy profesjonalne wsparcie techniczne. Po wygaśnięciu gwarancji klienci muszą zapłacić jedynie za koszt części zamiennych, nadal korzystając z usług konserwacyjnych po obniżonych cenach. Naszym celem jest pomoc klientom w obniżeniu kosztów operacyjnych i zwiększeniu wydajności produkcji dzięki niezawodnej jakości i kompleksowemu wsparciu posprzedażowemu. Niezależnie od tego, czy chodzi o zapytania techniczne, czy potrzeby konserwacyjne, nasz zespół ekspertów odpowie szybko, aby zapewnić, że Twój system zaworów zawsze będzie utrzymywał optymalną wydajność.
Jeśli interesują Cię nasze produkty, możesz zostawić tutaj swoje dane, a wkrótce się z Tobą skontaktujemy.