Design & Manufacture BS 6364, ISO 28921-1, MSS SP-134, ASME B16.34
Face-to-Face Dimension BS 6364 Table 1, ISO 5752 Series 11 (Extended)
End Connections ASME B16.5 (RF/RTJ), EN 1092-1, GB/T 9113, JB/T 79
Butt Weld Ends ASME B16.25, GB/T 12224
Socket Weld / Thread ASME B16.11, NPT/BSPT per ISO 7-1
Pressure Testing API 598, ISO 5208, BS 6364 Annex A (Cryogenic)



Description
TECHNICAL DATA SHEET
Forged Stainless Steel Cryogenic Floating Ball Valve
Series: DQ41F/Y / DQ61F/Y
Models: Reduced Bore / Full Bore, Side-Entry (Split Body)
This forged stainless steel cryogenic ball valve is specifically engineered for reliable shut-off and flow control of liquefied gases and cryogenic fluids down to -196°C. Designed in accordance with BS 6364, ISO 28921-1, and MSS SP-134 standards, it features a two-piece bolted body construction with extended bonnet and fully forged austenitic stainless steel components (ASTM A182 F304/F304L/F316L) to eliminate porosity and ensure structural integrity under extreme thermal cycling .
Caractéristiques principales:
|
Item |
Standard / Code |
|
Design & Manufacture |
BS 6364, ISO 28921-1, MSS SP-134, ASME B16.34 |
|
Face-to-Face Dimension |
BS 6364 Table 1, ISO 5752 Series 11 (Extended) |
|
End Connections |
ASME B16.5 (RF/RTJ), EN 1092-1, GB/T 9113, JB/T 79 |
|
Butt Weld Ends |
ASME B16.25, GB/T 12224 |
|
Socket Weld / Thread |
ASME B16.11, NPT/BSPT per ISO 7-1 |
|
Pressure Testing |
API 598, ISO 5208, BS 6364 Annex A (Cryogenic) |
|
Fugitive Emission |
ISO 15848-1 Class B |
|
Fire Safe (Optional) |
API 607 / ISO 10497 |
|
Antistatique |
ISO 28921-1, BS 5353 |
|
NACE |
MR0175 / ISO 15156 (Optional) |
|
SIL Rating |
SIL 3 Capable (IEC 61508) |
|
Paramètre |
Spécification |
|
Type de vanne |
Floating Ball, Side-Entry (2-Piece Split Body), Anti-blowout Stem |
|
Size Range |
DN15 ~ DN300 (½” ~ 12″) |
|
Pressure Classes |
ASME Class 150, 300, 600 (PN16 ~ PN100) |
|
Plage de température |
-196°C ~ +80°C (Standard Cryogenic) |
|
Design Temperature |
-196°C (Liquid Nitrogen) |
|
Minimum Design Temp |
-196°C (316L), -101°C (LC3), -46°C (LCB) |
|
Service Media |
LNG, LN₂, LO₂, LAr, LHe, Ethylene, Liquid Propane, Ammonia, CO₂, Hydrogen |
|
Flow Pattern |
Full Bore (Regular) / Reduced Bore (Optional) |
|
Flow Direction |
Uni-directional (Standard), Bi-directional (Optional) |
|
Opération |
Manual (Lever/Gear), Pneumatic (DA/SR), Electric |
|
Mounting |
ISO 5211 top flange for direct actuator mounting |
|
Insulation |
Extended bonnet suitable for cold box installation |
|
Composant |
Material (ASTM) |
Notes |
|
Body Halves |
A182 F304/F304L (Forged) |
Carbon ≤ 0.03%, cryogenic stabilization treated, -196°C impact ≥ 50J |
|
Bonnet (Extension) |
A182 F304/F304L (Forged) |
Extended length per BS 6364, integrally forged or welded construction |
|
Balle |
A182 F304/F304L (Forged) |
Chrome-nickel austenitic, surface Ra ≤ 0.4μm, floating design |
|
Tige |
A182 F304/F304L/F316L (Forged) |
Anti-blowout shoulder, cryogenic nitrogen hardening optional |
|
Seat Rings |
RPTFE (Glass/Carbon Fiber Reinforced) / PCTFE / PEEK |
Spring-energized for low-temp sealing |
|
Seal Carrier |
A182 F304/F304L |
– |
|
Stem Packing |
Graphite Foil + RPTFE, Live-loaded with Belleville springs |
Low emission, ISO 15848-1 Class B |
|
Gaskets |
Spiral Wound (SS316L/Graphite) |
– |
|
Body Bolting |
ASTM A193 B8M Class 2 (Stainless) |
High strength, low-temperature compatible |
|
Nuts |
ASTM A194 8M |
– |
|
Thrust Washer |
RPTFE / PTFE + Bronze |
Anti-extrusion, low friction |
|
Dispositif antistatique |
SS316L Spring + Plunger |
Resistance ≤ 10Ω |
|
Handle / Gearbox |
SS304 / Ductile Iron |
– |
Alternative Forged Materials (Upon Request):
Cryogenic Stabilization Process:
Purpose:
Impact Testing:
6.1 Flanged Type (DQ41F/Y) – PN16/PN40 / Class 150/300
Unit: mm (Reference dimensions – subject to manufacturer design)
|
DN |
Size (in) |
L (RF) |
L (RTJ) |
D (Class 150) |
D (Class 300) |
Bonnet Extension H |
Approx. Weight (kg) |
|
15 |
½” |
130 |
140 |
95 |
95 |
230 |
3.0 |
|
20 |
¾” |
140 |
152 |
105 |
105 |
260 |
4.0 |
|
25 |
1″ |
150 |
165 |
115 |
115 |
280 |
5.0 |
|
32 |
1¼” |
165 |
178 |
135 |
135 |
290 |
9.0 |
|
40 |
1½” |
180 |
190 |
145 |
145 |
320 |
11.0 |
|
50 |
2″ |
203 |
216 |
160 |
165 |
340 |
15.0 |
|
65 |
2½” |
222 |
241 |
180 |
190 |
370 |
19.0 |
|
80 |
3″ |
241 |
283 |
195 |
210 |
400 |
27.0 |
|
100 |
4″ |
305 |
305 |
215 |
255 |
450 |
38.0 |
|
150 |
6″ |
394 |
403 |
280 |
320 |
550 |
81.0 |
|
200 |
8″ |
457 |
502 |
345 |
380 |
680 |
95.0 |
|
250 |
10″ |
533 |
568 |
405 |
445 |
790 |
140.0 |
|
300 |
12″ |
610 |
648 |
485 |
520 |
890 |
200.0 |
Notes:
6.2 Socket Weld / Threaded Type (DQ61F/Y) – NPT/BSPT/SW
Unit: mm
|
DN |
Inch |
L |
d (Bore) |
D (Socket) |
D1 (Thread) |
H (Extension) |
W (Handle) |
|
15 |
½” |
92 |
13 |
36 |
21.8 |
230 |
160 |
|
20 |
¾” |
111 |
18 |
42 |
27.3 |
260 |
220 |
|
25 |
1″ |
127 |
23 |
52 |
33.8 |
280 |
220 |
|
32 |
1¼” |
140 |
28 |
60 |
42.6 |
290 |
250 |
|
40 |
1½” |
152 |
35 |
68 |
48.7 |
320 |
250 |
|
50 |
2″ |
178 |
45 |
80 |
61.2 |
340 |
350 |
Source:
Forged A182 F304/F304L – ASME B16.34
|
Temperature (°C) |
Class 150 (psi) |
Class 300 (psi) |
Class 600 (psi) |
|
-29 to +38 |
285 |
740 |
1480 |
|
+50 |
270 |
705 |
1410 |
|
+100 |
235 |
615 |
1230 |
|
-196°C (Derated) |
230 |
600 |
1200 |
Critical Notes:
|
Test Type |
Standard |
Criteria |
|
Shell Hydrostatic Test |
API 598 / ISO 5208 |
1.5 × rated pressure at ambient, no visible leakage |
|
High-Pressure Pneumatic Test |
API 598 |
0.6 MPa (80 psi) air, soap bubble test |
|
Cryogenic Seat Leakage Test |
BS 6364 Annex A |
Valve immersed in LN₂ (-196°C), 1.1× rated pressure, max leakage: 0.1 Nm³/hr × DN (mm) for gas |
|
High-Performance Cryogenic Leakage |
AOKAVI / ISO 28921-1 |
≤ 1×10⁻⁹ mL/min (Helium) at -196°C |
|
Fugitive Emission (Stem) |
ISO 15848-1 Class B |
≤ 10⁻⁵ mbar·L/s (Helium) |
|
Anti-Static Test |
ISO 28921-1 |
Resistance ≤ 10Ω between stem and body |
|
Fire Safe (Optional) |
API 607 |
Per API 607 7th Edition |
|
DN |
Taille |
Torque (N·m) @ ΔP=40 bar |
Actuator Recommendation |
|
15 |
½” |
8 – 12 |
Manual Lever / Small Pneumatic |
|
25 |
1″ |
20 – 30 |
Levier manuel |
|
50 |
2″ |
80 – 120 |
Manual Lever / Gear |
|
80 |
3″ |
180 – 250 |
Gear / Pneumatic |
|
100 |
4″ |
300 – 400 |
Gear / Pneumatic |
|
150 |
6″ |
700 – 900 |
Gearbox / Pneumatic |
Notes:
Extended Bonnet (Long Neck):
Pressure Relief Mechanism:
Dispositif antistatique:
Oxygen Service Cleaning:
|
Industry |
Typical Media |
Température |
|
LNG / LPG |
Methane, Ethane, Propane, Butane |
-162°C to -46°C |
|
Industrial Gases (Air Separation) |
Liquid Nitrogen (LN₂), Liquid Oxygen (LO₂), Liquid Argon (LAr) |
-196°C to -183°C |
|
Hydrogen Energy |
Liquid Hydrogen (LH₂) |
-253°C (Inconel/Ti req’d) |
|
Petrochemical |
Ethylene, Propylene |
-104°C |
|
Refrigeration |
Ammonia (R717), CO₂ (R744) |
-46°C to -78°C |
|
Cryogenic Storage |
Liquid Helium (LHe) |
-269°C (Special alloy) |
|
Aerospace |
Rocket propellants (LO₂, LH₂) |
-253°C to -183°C |
|
Pharmaceutical / Biotech |
Liquid nitrogen freezing |
-196°C |
|
Certification |
Scope |
Availability |
|
BS 6364 |
Cryogenic valve design & testing |
Standard |
|
ISO 28921-1 |
Industrial cryogenic valves |
Standard |
|
PED 2014/68/EU |
Category III, Module H |
Optional |
|
TA-Luft (VDI 2440) |
Fugitive emission |
Optional |
|
API 607 |
Fire safe testing |
Optional |
|
NACE MR0175 |
Sour service |
Optional |
|
ATEX 2014/34/EU |
Explosive atmospheres (Zone 1/2) |
Optional |
|
ISO 9001:2015 |
Quality management |
Standard |
|
EN 10204 3.1/3.2 |
Material certification |
Optional |
To ensure correct valve selection for your cryogenic application, please specify:
GARANTIE :
SAVVY VALVES s'engage à fournir des produits d'une qualité exceptionnelle et un service après-vente sans souci. Nos vannes sont garanties pour une durée de vie minimale de 12 mois, période durant laquelle nous fournissons gratuitement toutes les pièces de rechange nécessaires et des instructions d'entretien détaillées. Pendant la période de garantie, en cas de dommage non causé par l'homme, nous remplaçons gratuitement les composants et fournissons une assistance technique professionnelle. Après l'expiration de la garantie, seuls les pièces de rechange sont à votre charge, tout en bénéficiant de services de maintenance à prix réduits. Notre objectif est d'aider nos clients à réduire leurs coûts d'exploitation et à optimiser leur production grâce à une qualité fiable et un service après-vente complet. Qu'il s'agisse de questions techniques ou de besoins de maintenance, notre équipe d'experts répondra rapidement pour garantir le fonctionnement optimal de votre système de vannes.
Si vous êtes intéressé par nos produits, vous pouvez choisir de laisser vos informations ici et nous vous contacterons sous peu.