DN250-PN16 Wafer Dual Plate Check Valve

DN250-PN16 Wafer Dual Plate Check Valve

Product Name Wafer Dual Plate Check Valve / Wafer Double Door Check Valve
Type/Series General Purpose (e.g., Series equivalent to Pegler V909, Oventrop, Honeywell Impact)
Nominal Diameter DN250 (10 inches)
Nominal Pressure PN16
End Connection Wafer Type Design, designed for installation between PN16 flanges (According to EN 1092-2, ISO 7005-2, or ASME B16.5 Class 150)
Design Structure Dual Plate / Double Door with Spring-Loaded Hinge

  • aboutimg3
  • aboutimg4
  • aboutimg5


Technical Data Sheet: DN250-PN16 Wafer Dual Plate Check Valve

Item

Specyfikacja

Product Name

Wafer Dual Plate Check Valve / Wafer Double Door Check Valve

Type/Series

General Purpose (e.g., Series equivalent to Pegler V909, Oventrop, Honeywell Impact)

Nominal Diameter

DN250 (10 inches)

Nominal Pressure

PN16

End Connection

Wafer Type Design, designed for installation between PN16 flanges (According to EN 1092-2, ISO 7005-2, or ASME B16.5 Class 150)

Design Structure

Dual Plate / Double Door with Spring-Loaded Hinge

Technical Parameters

Parametr

Value

Remarks

Ocena ciśnienia

PN 16 / 16 bar

Maximum allowable working pressure

Shell Test Pressure

24 bar

Hydrostatic test

Seat Test Pressure

17.6 bar

Hydrostatic test

Suitable Media

Water, Non-corrosive liquids, HVAC water, Potable water

Not suitable for heavily polluted media or strong acids/bases unless specified

Medium Temp. Range

-10°C to +110°C (Standard)

Dependent on seat material

-29°C to +180°C (Special Seals)

Flow Coefficient (Kv)

Approx. 2000 – 2330 m³/h

Flow rate at ΔP = 1 bar, fully open

Installation Position

Horizontal or Vertical

For horizontal lines, hinge pin must be horizontal/vertical; For vertical lines, flow must be upwards

Flow Direction

Jednokierunkowy

Must match arrow marking on body

Materials of Construction

Część

Material

Remarks / Alternative

Ciało

Ductile Iron / Cast Iron

e.g., EN-GJS-450-10 (GGG40), EN-GJL-250

Discs / Plates

Stainless Steel / Coated Ductile Iron

Common: SS304, SS316; or Epoxy-coated Ductile Iron

Shaft / Pin

Stainless Steel

e.g., SS420, SS316

Springs

Stainless Steel

Seat / Seal

EPDM (Ethylene Propylene Diene Monomer)

Standard Option: Suitable for water, wastewater, mild chemicals

NBR (Nitrile Butadiene Rubber)

Suitable for oils and fuels

PTFE (Polytetrafluoroethylene)

High temperature or corrosive media

Coating

Epoxy / Anti-corrosion Paint

Standard color: Blue (RAL 5005) or as specified

Face-to-Face & Installation Dimensions (mm)

The face-to-face dimension (L) is critical for correct installation between flanges.

Dimension

Value

Standard / Reference

Face-to-Face Length (L)

108 mm

According to EN 558-1 Series 49 (formerly DIN 3202 K3)

114 mm

Alternative dimension depending on manufacturer design

Body Diameter (D)

~328 mm

Maximum outer diameter to fit between PN16 DN250 flanges

Reference: Flange Bolt Circle Dia. (K)

355 mm

Corresponds to EN 1092-2 PN16 DN250 flange

Reference: Flange Bolt Holes

12 – Ø26 mm

Corresponds to EN 1092-2 PN16 DN250 flange

Approx. Weight

~19.5 kg

Range varies by manufacturer (approx. 13.8kg – 30kg)

Dimensional Sketch (Reference Only):

text

      _______

  <-->|     |<--  L (Face-to-Face Length)

   |  |_____|  |

   |            |

   |   D (Body Diameter / Max. Width)  |

   |            |

   |____________|

      (Flow ↑)

Applicable Standards

  • Design & Manufacture: EN 16767, API 594, BS 5153, JB/T 8937
  • Twarzą w twarz: EN 558-1 (Series 49), ISO 5752, DIN 3202 K3
  • Flange Connection: EN 1092-2, ISO 7005-2, ASME B16.5 Class 150 (compatible)
  • Inspection & Testing: EN 12266, API 598, ISO 5208

Key Features & Applications

Key Features:

  • Compact & Lightweight: The wafer design saves space and reduces weight compared to swing check valves.
  • Quick Closing / Non-Slam: Short spring-assisted disc travel minimizes the risk of water hammer and prevents reverse flow effectively.
  • Low Pressure Drop: Streamlined body and disc design offer low resistance to flow.
  • Versatile Installation: Can be installed in both horizontal and vertical pipelines.

Main Applications:

  • Water Supply and Distribution
  • HVAC Systems (Heating, Ventilation, and Air Conditioning)
  • Industrial Cooling Water Circuits
  • Pump Protection (Preventing backflow damage)

Notes:

  • This datasheet is based on general industry specifications. For final installation, please refer to the official datasheet of the specific manufacturer (e.g., Flowserve, Bray, Emerson, KSB).
  • When ordering, please specify the required seat material (EPDM, NBR, PTFE, etc.) based on your media temperature and chemical compatibility.

GWARANCJA:

SAVVY VALVES zobowiązuje się do dostarczania wyjątkowej jakości produktów i bezproblemowej obsługi posprzedażowej. Gwarantujemy, że nasze zawory zapewnią minimalny okres eksploatacji wynoszący 12 miesięcy, podczas którego dostarczymy bezpłatnie wszystkie niezbędne części zamienne i szczegółowe instrukcje dotyczące konserwacji. W okresie gwarancyjnym, jeśli wystąpią jakiekolwiek uszkodzenia niespowodowane przez człowieka, wymienimy komponenty bezpłatnie i zapewnimy profesjonalne wsparcie techniczne. Po wygaśnięciu gwarancji klienci muszą zapłacić jedynie za koszt części zamiennych, nadal korzystając z usług konserwacyjnych po obniżonych cenach. Naszym celem jest pomoc klientom w obniżeniu kosztów operacyjnych i zwiększeniu wydajności produkcji dzięki niezawodnej jakości i kompleksowemu wsparciu posprzedażowemu. Niezależnie od tego, czy chodzi o zapytania techniczne, czy potrzeby konserwacyjne, nasz zespół ekspertów odpowie szybko, aby zapewnić, że Twój system zaworów zawsze będzie utrzymywał optymalną wydajność.

 


Jeśli interesują Cię nasze produkty, możesz zostawić tutaj swoje dane, a wkrótce się z Tobą skontaktujemy.