DN250-PN16 Wafer Dual Plate Check Valve

DN250-PN16 Wafer Dual Plate Check Valve

Product Name Wafer Dual Plate Check Valve / Wafer Double Door Check Valve
Type/Series General Purpose (e.g., Series equivalent to Pegler V909, Oventrop, Honeywell Impact)
Nominal Diameter DN250 (10 inches)
Nominal Pressure PN16
End Connection Wafer Type Design, designed for installation between PN16 flanges (According to EN 1092-2, ISO 7005-2, or ASME B16.5 Class 150)
Design Structure Dual Plate / Double Door with Spring-Loaded Hinge

  • aboutimg3
  • aboutimg4
  • aboutimg5


Technical Data Sheet: DN250-PN16 Wafer Dual Plate Check Valve

Item

Đặc điểm kỹ thuật

Product Name

Wafer Dual Plate Check Valve / Wafer Double Door Check Valve

Type/Series

General Purpose (e.g., Series equivalent to Pegler V909, Oventrop, Honeywell Impact)

Nominal Diameter

DN250 (10 inches)

Nominal Pressure

PN16

End Connection

Wafer Type Design, designed for installation between PN16 flanges (According to EN 1092-2, ISO 7005-2, or ASME B16.5 Class 150)

Design Structure

Dual Plate / Double Door with Spring-Loaded Hinge

Technical Parameters

Tham số

Value

Nhận xét

Xếp hạng áp suất

PN 16 / 16 bar

Maximum allowable working pressure

Shell Test Pressure

24 bar

Hydrostatic test

Seat Test Pressure

17.6 bar

Hydrostatic test

Suitable Media

Water, Non-corrosive liquids, HVAC water, Potable water

Not suitable for heavily polluted media or strong acids/bases unless specified

Medium Temp. Range

-10°C to +110°C (Standard)

Dependent on seat material

-29°C to +180°C (Special Seals)

Flow Coefficient (Kv)

Approx. 2000 – 2330 m³/h

Flow rate at ΔP = 1 bar, fully open

Installation Position

Horizontal or Vertical

For horizontal lines, hinge pin must be horizontal/vertical; For vertical lines, flow must be upwards

Flow Direction

Một chiều

Must match arrow marking on body

Materials of Construction

Thành phần

Vật liệu

Remarks / Alternative

Thân hình

Ductile Iron / Cast Iron

e.g., EN-GJS-450-10 (GGG40), EN-GJL-250

Discs / Plates

Stainless Steel / Coated Ductile Iron

Common: SS304, SS316; or Epoxy-coated Ductile Iron

Shaft / Pin

Stainless Steel

e.g., SS420, SS316

Springs

Stainless Steel

Seat / Seal

EPDM (Ethylene Propylene Diene Monomer)

Standard Option: Suitable for water, wastewater, mild chemicals

NBR (Nitrile Butadiene Rubber)

Suitable for oils and fuels

PTFE (Polytetrafluoroethylene)

High temperature or corrosive media

Coating

Epoxy / Anti-corrosion Paint

Standard color: Blue (RAL 5005) or as specified

Face-to-Face & Installation Dimensions (mm)

The face-to-face dimension (L) is critical for correct installation between flanges.

Dimension

Value

Standard / Reference

Face-to-Face Length (L)

108 mm

According to EN 558-1 Series 49 (formerly DIN 3202 K3)

114 mm

Alternative dimension depending on manufacturer design

Body Diameter (D)

~328 mm

Maximum outer diameter to fit between PN16 DN250 flanges

Reference: Flange Bolt Circle Dia. (K)

355 mm

Corresponds to EN 1092-2 PN16 DN250 flange

Reference: Flange Bolt Holes

12 – Ø26 mm

Corresponds to EN 1092-2 PN16 DN250 flange

Approx. Weight

~19.5 kg

Range varies by manufacturer (approx. 13.8kg – 30kg)

Dimensional Sketch (Reference Only):

text

      _______

  <-->|     |<--  L (Face-to-Face Length)

   |  |_____|  |

   |            |

   |   D (Body Diameter / Max. Width)  |

   |            |

   |____________|

      (Flow ↑)

Applicable Standards

  • Design & Manufacture: EN 16767, API 594, BS 5153, JB/T 8937
  • Đối mặt trực tiếp: EN 558-1 (Series 49), ISO 5752, DIN 3202 K3
  • Flange Connection: EN 1092-2, ISO 7005-2, ASME B16.5 Class 150 (compatible)
  • Inspection & Testing: EN 12266, API 598, ISO 5208

Key Features & Applications

Key Features:

  • Compact & Lightweight: The wafer design saves space and reduces weight compared to swing check valves.
  • Quick Closing / Non-Slam: Short spring-assisted disc travel minimizes the risk of water hammer and prevents reverse flow effectively.
  • Low Pressure Drop: Streamlined body and disc design offer low resistance to flow.
  • Versatile Installation: Can be installed in both horizontal and vertical pipelines.

Main Applications:

  • Water Supply and Distribution
  • HVAC Systems (Heating, Ventilation, and Air Conditioning)
  • Industrial Cooling Water Circuits
  • Pump Protection (Preventing backflow damage)

Notes:

  • This datasheet is based on general industry specifications. For final installation, please refer to the official datasheet of the specific manufacturer (e.g., Flowserve, Bray, Emerson, KSB).
  • When ordering, please specify the required seat material (EPDM, NBR, PTFE, etc.) based on your media temperature and chemical compatibility.

CAM KẾT:

SAVVY VALVES cam kết cung cấp chất lượng sản phẩm vượt trội và dịch vụ sau bán hàng không phải lo lắng. Van của chúng tôi được đảm bảo cung cấp tuổi thọ tối thiểu là 12 tháng, trong thời gian đó chúng tôi sẽ cung cấp tất cả các phụ tùng thay thế cần thiết và hướng dẫn bảo trì chi tiết miễn phí. Trong thời gian bảo hành, nếu xảy ra bất kỳ hư hỏng nào không phải do con người gây ra, chúng tôi sẽ thay thế các thành phần miễn phí và cung cấp hỗ trợ kỹ thuật chuyên nghiệp. Sau khi hết hạn bảo hành, khách hàng chỉ cần trả chi phí cho các phụ tùng thay thế, trong khi vẫn được hưởng lợi từ các dịch vụ bảo trì giảm giá. Mục tiêu của chúng tôi là giúp khách hàng giảm chi phí vận hành và nâng cao hiệu quả sản xuất thông qua chất lượng đáng tin cậy và hỗ trợ sau bán hàng toàn diện. Cho dù là yêu cầu kỹ thuật hay nhu cầu bảo trì, nhóm chuyên gia của chúng tôi sẽ phản hồi nhanh chóng để đảm bảo hệ thống van của bạn luôn duy trì hiệu suất tối ưu.

 


Nếu bạn quan tâm đến sản phẩm của chúng tôi, bạn có thể để lại thông tin tại đây và chúng tôi sẽ sớm liên hệ với bạn.