3“ 150LB PFA Fully Internal Lined Butterfly Valves

3“ 150LB PFA Fully Internal Lined Butterfly Valves

Nominal Size 3″ (DN80)
Pressure Class Class 150LB (PN10/PN16)
Valve Type Concentric / Resilient Seated Butterfly Valve
Structure Fully Internal Lined
Connection Type Wafer or Lug
Design Standard API 609, MSS SP-67, ISO 5752
Face-to-Face API 609 Table 2 / ISO 5752 Series 20
Flange Standard ASME B16.5 Class 150
Testing Standard API 598 / ISO 5208 Rate A
Operation Lever / Gearbox / Pneumatic / Electric

  • aboutimg3
  • aboutimg4
  • aboutimg5


Technical Data Sheet: 3″ 150LB PFA Fully Internal Lined Butterfly Valve

  1. Product Description

This 3-inch, Class 150 flanged (Wafer/Lug) butterfly valve features a body and disc fully encapsulated with PFA (Perfluoroalkoxy) lining. It is specifically designed for highly corrosive chemicals, high-purity media, and severe service conditions, ensuring absolute isolation of the metal components from the process fluid and achieving bi-directional zero leakage.

  1. Technical Specifications

Parameter

Spesifikasi

Ukuran Nominal

3″ (DN80)

Pressure Class

Class 150LB (PN10/PN16)

Jenis Katup

Concentric / Resilient Seated Butterfly Valve

Struktur

Fully Internal Lined

Connection Type

Wafer or Lug

Design Standard

API 609, MSS SP-67, ISO 5752

Tatap Muka

API 609 Table 2 / ISO 5752 Series 20

Flange Standard

ASME B16.5 Class 150

Testing Standard

API 598 / ISO 5208 Rate A

Operasi

Lever / Gearbox / Pneumatic / Electric

  1. Materials of Construction

Komponen

Bahan

Tubuh

Ductile Iron (DI) / Carbon Steel (WCB) / Stainless Steel (CF8/CF8M)

Body Lining

PFA (Molded, 3mm min. thickness)

Cakram

Stainless Steel (SS304/SS316) + PFA Encapsulated

Tangkai

Stainless Steel (SS304/SS316/17-4PH), Blow-out Proof Design

Kursi

Integrated PFA Lining (Molded together with body lining)

Bearing/Bushing

PTFE Composite (Self-lubricating)

Sealing Elements

FPM (Viton) / EPDM / PTFE Encapsulated

  1. Performance Data
  • Operating Temperature: -29°C to +180°C (-20°F to +356°F)
  • Kelas Kebocoran: Bi-directional Zero Leakage (ISO 5208 Rate A / ANSI FCI 70-2 Class VI)
  • Suitable Media: Strong acids (Sulfuric, Hydrochloric, Hydrofluoric), strong alkalis, organic solvents, high-purity water, wet chlorine gas, etc.
  • Vacuum Service: Applicable, full vacuum rated within -10°C to +160°C (+14°F to +320°F)
  • Lining Integrity Test: 100% High Voltage Spark Test (15kV or 10kV DC) performed on every valve to ensure zero pinhole defects.
  1. Pressure-Temperature Ratings

(Based on Class 150LB and PFA mechanical properties, typical values)

Working Temperature

Maximum Allowable Working Pressure

-29°C ~ +50°C (-20°F ~ +122°F)

16.0 bar (232 psi)

+100°C (212°F)

14.0 bar (203 psi)

+150°C (302°F)

11.0 bar (159 psi)

+180°C (356°F)

8.5 bar (123 psi)

*Note: Final pressure-temperature ratings must comply with ASME B16.34 and the lining manufacturer’s specific data.*

  1. Fitur Utama
  • Full Isolation: The body and disc are completely encapsulated with PFA, eliminating any contact between the metal and the media. Provides superior anti-corrosion performance.
  • Low Torque Operation: The extremely low friction coefficient of the PFA surface, combined with PTFE bearings, results in low operating torque and prevents sticking.
  • Bi-directional Sealing: The spherically machined disc matched with the integrated PFA seat ensures bubble-tight sealing in both directions.
  • Blow-out Proof Stem: Features an integral safety step design, preventing the stem from being ejected under high pressure or differential pressure.
  • Standardized Mounting: The top flange adheres to ISO 5211 standards, allowing direct mounting of various actuators without the need for complex brackets.
  1. Precautions & Notes
  1. Slurry/Media: Avoid media containing hard solid particles, as this may scratch or damage the PFA lining surface.
  2. Installation: Flange bolts must be tightened evenly and symmetrically. The Lug-style design allows for downstream pipe disconnection while the upstream side remains pressurized.
  3. Storage: Valves should be stored in a dry, ventilated indoor environment, slightly open, protected from direct sunlight and any physical impact that could damage the lining.

This technical data sheet is based on general industry standards and typical product specifications. Exact dimensions and confirmed performance parameters shall be subject to the final vendor-certified drawing.

JAMINAN:

SAVVY VALVES berkomitmen untuk memberikan kualitas produk yang luar biasa dan layanan purnajual yang bebas masalah. Katup kami dijamin memberikan masa pakai minimal 12 bulan, di mana kami akan menyediakan semua suku cadang yang diperlukan dan petunjuk perawatan terperinci secara gratis. Dalam masa garansi, jika terjadi kerusakan yang bukan disebabkan oleh manusia, kami akan mengganti komponen tanpa biaya dan memberikan dukungan teknis yang profesional. Setelah masa garansi berakhir, pelanggan hanya perlu membayar biaya suku cadang, sambil tetap mendapatkan keuntungan dari layanan perawatan dengan harga diskon. Tujuan kami adalah membantu klien mengurangi biaya operasional dan meningkatkan efisiensi produksi melalui kualitas yang andal dan dukungan purnajual yang komprehensif. Baik untuk pertanyaan teknis maupun kebutuhan perawatan, tim ahli kami akan segera merespons untuk memastikan sistem katup Anda mempertahankan kinerja yang optimal setiap saat.

Jika Anda tertarik dengan produk kami, Anda dapat memilih untuk meninggalkan informasi Anda di sini, dan kami akan segera menghubungi Anda.