Keterangan
German Standard Lift Check Valve Technical Data Sheet
A105 Material DN15 PN16 Welded Flange
- General Information
|
Item
|
Spesifikasi
|
|
Jenis Katup
|
Lift Check Valve
|
|
Design Standard
|
DIN 3356
|
|
Ukuran Nominal
|
DN15
|
|
Pressure Class
|
PN16
|
|
Structure Type
|
Lift Type, Bolted Bonnet
|
|
Connection Type
|
Welded Flange
|
|
Installation
|
Horizontal Piping
|
|
Bahan Tubuh
|
ASTM A105 (Forged Carbon Steel)
|
- Applicable Standards
|
Item
|
Standard Code
|
|
Design & Manufacturing
|
DIN 3356
|
|
Face-to-Face / End-to-End
|
DIN 3202
|
|
Flanged Connections
|
DIN 2543-2546
|
|
Test & Inspection
|
DIN 3230
|
- Main Design Features
- Operating Principle: Automatically opens and closes the disc by medium flow. When medium flows in the specified direction, disc opens under medium pressure. When backflow occurs, disc closes against seat to prevent reverse flow
- Disc Structure: Disc moves vertically along the body centerline, reliable operation, suitable for small bore applications
- Sealing Surface: Wear-resistant, corrosion-resistant, long service life
- Installation Requirement: Suitable for horizontal pipelines only, disc closes by gravity
- Konstruksi Bodi: Forged steel body, dense structure, high strength, no casting defects
- Main Component Materials
|
Item
|
Part Name
|
Bahan
|
Standard/Remark
|
|
1
|
Tubuh
|
ASTM A105
|
Forged Carbon Steel
|
|
2
|
Bonnet
|
ASTM A105
|
Forged Carbon Steel
|
|
3
|
Cakram
|
2Cr13 / A105+STL
|
Stainless Steel or Hardfaced
|
|
4
|
Kursi
|
Integral / STL Hardfaced
|
Machined directly on body or hardfaced
|
|
5
|
Gasket
|
SS + Flexible Graphite
|
Spiral Wound
|
|
6
|
Stud Bolt
|
ASTM A193 Gr.B7
|
Alloy Steel
|
|
7
|
Hex Nut
|
ASTM A194 Gr.2H
|
Heavy Hex Nut
|
- Technical Parameters & Dimensions
5.1 Performance Specifications
|
Item
|
Parameter
|
|
Nominal Pressure (PN)
|
1.6 MPa
|
|
Shell Test Pressure
|
2.4 MPa
|
|
Seal Test Pressure
|
1.76 MPa
|
|
Kisaran Suhu
|
-20℃ ~ 350℃
|
|
Applicable Media
|
Water, Steam, Oil, etc.
|
5.2 Dimensions (DN15 PN16 Welded Flange)
|
Dimension
|
Value
|
Remark
|
|
End-to-End Length (L)
|
130 mm
|
Per DIN 3202 standard
|
|
Height (H)
|
Approx. 70 mm
|
Reference value
|
|
Flange Diameter (D)
|
95 mm
|
Per DIN 2543 standard
|
|
Flange Sealing Face
|
Raised Face
|
Suitable for welding connection
|
|
Weight
|
Approx. 2.4 kg
|
Reference value, may vary by manufacturer
|
5.3 End Connection Details
- Welded Flange: Flange dimensions per DIN 2543-2546, Raised Face sealing, flange to be welded to pipe
- Test & Inspection (DIN 3230)
|
Test Item
|
Test Pressure
|
Medium
|
Acceptance Criteria
|
|
Shell Test
|
2.4 MPa
|
Water
|
No visible leakage
|
|
Seal Test
|
1.76 MPa
|
Water or Air
|
No visible leakage
|
|
Test Duration
|
Per DIN 3230
|
—
|
Hold time conforms to standard
|
- Marking & Supply
- Flow Direction: Clear flow direction arrow marking on body
- Valve Marking: Nameplate to include nominal size, pressure class, material, design standard, etc.
- Cleaning & Protection: Valves internally and externally cleaned, flange faces covered with protectors and coated with rust preventive
- Documentation: Material certificates, pressure test reports, declaration of conformity provided with shipment
JAMINAN:
SAVVY VALVES berkomitmen untuk memberikan kualitas produk yang luar biasa dan layanan purnajual yang bebas masalah. Katup kami dijamin memberikan masa pakai minimal 12 bulan, di mana kami akan menyediakan semua suku cadang yang diperlukan dan petunjuk perawatan terperinci secara gratis. Dalam masa garansi, jika terjadi kerusakan yang bukan disebabkan oleh manusia, kami akan mengganti komponen tanpa biaya dan memberikan dukungan teknis yang profesional. Setelah masa garansi berakhir, pelanggan hanya perlu membayar biaya suku cadang, sambil tetap mendapatkan keuntungan dari layanan perawatan dengan harga diskon. Tujuan kami adalah membantu klien mengurangi biaya operasional dan meningkatkan efisiensi produksi melalui kualitas yang andal dan dukungan purnajual yang komprehensif. Baik untuk pertanyaan teknis maupun kebutuhan perawatan, tim ahli kami akan segera merespons untuk memastikan sistem katup Anda mempertahankan kinerja yang optimal setiap saat.